canmove, Confirmed users
937
edits
No edit summary |
|||
| Line 22: | Line 22: | ||
== Inhibition of Data Output == | == Inhibition of Data Output == | ||
All data output via the data output interface is inhibited when the NSS cryptographic module is in the | All data output via the data output interface is inhibited when the NSS cryptographic module is in the Error state or performing self-tests. | ||
=== In Error State === | === In Error State === | ||
When the NSS cryptographic module is in the | When the NSS cryptographic module is in the Error state, most PKCS #11 functions, including all the functions that output data via the data output interface, do nothing and return the CKR_DEVICE_ERROR error code immediately. Only the functions that shut down and restart the module, reinitialize the module, or output status information can be invoked in the Error state: FC_GetFunctionList, FC_Initialize, FC_Finalize, FC_GetInfo, FC_GetSlotList, FC_GetSlotInfo, FC_GetTokenInfo, FC_InitToken, FC_CloseSession, FC_CloseAllSessions, and FC_WaitForSlotEvent. | ||
=== During Self-Tests === | === During Self-Tests === | ||