Following are the requirements for the ammeter board that will be included in the second revision of the battery harness.
Note that this is a work in progress - this will be updated when the requirements are finalized...
Requirements:
- handle DC current of up to 2 amps from a single cell lithium battery
- precision <= 1 mA
- be able to measure voltage as well as instantaneous current draw
- high sample rate (1 kHz)
- ability to programatically disconnect and reconnect the battery
- push capability, where we can ask to start receiving data at a given rate over the usb link