NSSCryptoModuleSpec/Section 2: Module Ports and Interfaces: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
| Line 78: | Line 78: | ||
| Draft | | Draft | ||
|- | |- | ||
| '''Output of plaintext cryptographic keys or unprotected CSPs''' | | '''Output of plaintext cryptographic keys or unprotected CSPs on physical ports''' | ||
| | | | ||
[http://wiki.mozilla.org/VE_02#VE.02.14.01 VE.02.14.01 ] | [http://wiki.mozilla.org/VE_02#VE.02.14.01 VE.02.14.01 ] | ||
| (N/A) | | (N/A) | ||
| Draft | | Draft | ||
|} | |} | ||
Revision as of 04:27, 21 May 2006
This is a draft
|
Document Description |
DTR Section |
Assessment |
Status |
|---|---|---|---|
| Specification of all physical ports and logical interfaces | Module Interfaces | Draft | |
| Information flows and logical data paths | The information flows of the NSS module and logical paths used by input and output data are specified in:
|
Draft | |
| Mapping between logical interfaces and physical input/output/ports | (N/A) | Draft | |
| Logical interfaces |
VE.02.02.01 |
Logical Interfaces | Draft |
| External input or output devices | (N/A) The NSS module doesn't use any external input or output devices. | Draft | |
| Describe how data ouput is inhibited | Inhibition of Data Output | Draft | |
| Electrical power port | (N/A) The NSS module uses the power port of the general purpose computer it runs on. | Draft | |
| Describe how output data path is disconnected | Disconnecting the Output Data Path From Key Processes | Draft | |
| Output of plaintext cryptographic keys or unprotected CSPs on physical ports | (N/A) | Draft |
Return to: NSSCryptoModuleSpec