Confirmed users
3,990
edits
| Line 161: | Line 161: | ||
This error appears before logging in. I believe you can only stop "the installation" and be able to access the machine. | This error appears before logging in. I believe you can only stop "the installation" and be able to access the machine. | ||
[[File:OPSI_Pre-login_loader_error.png|300px|thumb|center|error: HTTP/1.1 401 Unauthorized]] | |||
bhearsum: This usually means that the slave is talking to the wrong opsi server, | |||
or that the hostkey on the slave doesn't match the one the server. | |||
* Check with which master is talking to | * Check with which master the slave is talking to | ||
** Open regedit and browse to HKEY_LOCAL_MACHINE\SOFTWARE\opsi.org\pcptch | ** Open regedit and browse to HKEY_LOCAL_MACHINE\SOFTWARE\opsi.org\pcptch | ||
** "opsiServiceURL" key should point to XXX for production or "https://10.2.71.216:4447" for staging. | ** "opsiServiceURL" key should point to XXX for production or "https://10.2.71.216:4447" for staging. | ||
** I believe rebooting should be good enough (not verified - armenzg) | |||
*** Further instructions are explained in [[ReferencePlatforms/Win32#Change_OPSI_server_.28staging_slaves_only.29|Win32#Change OPSI server]] | |||
* Check that the hostkeys on the master and the slave are the same | * Check that the hostkeys on the master and the slave are the same | ||
** in master: /etc/opsi/pckeys | ** in master: /etc/opsi/pckeys | ||
** in slave: C:\Program Files\opsi.org\preloginloader\cfg\locked.cfg | ** in slave: C:\Program Files\opsi.org\preloginloader\cfg\locked.cfg | ||
** TODO determine how to fix this case | |||
=== How to update the opt_pcbin drive mapping password === | === How to update the opt_pcbin drive mapping password === | ||